Anemometers and Windvanes in action!
Windspeed Ltd (Vector Instruments), 113 Marsh Road, RHYL, N. Wales, LL18 2AB, United Kingdom.
Windspeed Limited
Click for info on: Wind Speed sensors Click for info on: Wind Direction Sensors Click for info on: Masts + Mountings Click for info on: Air Temperature sensors Click for info on: Masts + Mountings Anemometer, Windvane and Air Temperature sensors
 Saturday, November 23 2024  Home [arrow]  Products [arrow]  Anemometers [arrow]  A100K, A100M, A100S Search site:  

Latest Weather...
(Rhyl, N.Wales, UK)
Wind Speed:  11.4 mph
Wind Direction:  186 °
Air Temp.:  4.8 °C
Rel. Humidity:  100 %
(updated at: 08:02 UTC)



Please call/email us if you need:





Translate using Google:
====
====
====
======


Notes:
This website requires Javascript and Cookies to be enabled for correct operation. Privacy Policy...

Use subject to Terms & Conditions.


GDPR: to request or decline communications containing marketing, news & updates from us, click HERE.
Celebrating more than 50 years manufacturing & servicing High Quality Vector Instruments Anemometers and Windvanes at Windspeed Ltd
A100K, A100M and A100S Anemometers
 
Datasheet: login to download This anemometer provides a pulse/frequency output signal suitable for direct measurement in Knots, Metres/second or run of wind when connected to a counter, PLC or data logger and is often used in applications where wind speed is required as an input to a PLC which is controlling equipment such as cranes, sprayers or water fountains.

The 3-cup R30 rotor drives a slotted disk interrupting a light-beam generating a stream of pulses. The A100K, A100M and A100S have disks with different numbers of slots and differently calibrated rotors to obtain the different output scalings.

It's electronics are intended to operate from the 12V and 24V DC supplies commonly available at industrial sites, and anti-surge protection is built-in. With 24V DC supply, 24V pulses are generated which are ideal as inputs to a PLC which can count pulses or measure frequency to determine the wind speed using this robust instrument.

Construction is from anodised aluminium alloys, stainless steels and weather resisting plastics for exposed parts. Precision corrosion resistant ball-races and a stainless steel shaft enable the R30 rotor response to produce a highly sensitive yet robust instrument suitable for continuous exposure to the weather.

Options for this anemometer include:
Note: /WR, /HE-1 and /HE-2 are not recommended for high precision applications.

The recommended mounting adaptors for use with this instrument are our type 405 and 405-1 series.

This instrument is commonly used in conjunction with our W200P Windvane.

Specification Highlights:

  • Threshold:
  • 0.15m/s
  • Maximum Windspeed:
  • over 75m/s (146Kts)
  • Temperature Range:
  • -50 to +70 °C
  • Accuracy:
  • 1% of reading between 10 and 55m/s, 2% above 55m/s. 0.1m/s for 0.1..10m/s
  • Distance Constant:
  • 2.3m +/-10% (R30 rotor)
  • Supply Voltage:
  • 10..30V DC ( @ 30mA typical at 12V DC)
  • Output Signal:
  • Squarewave (voltage levels = <0.1V and supply voltage approx.)
  • Output Resistance:
  • 3.3K Ohms
  • Anti-Surge:
  • Built-in
  • Duty Cycle:
  • 50% (A100K: +/- 20%, A100M: +/- 10%, A100S: +/- 5%)
  • A100K Output Cal.:
  • 10Hz per Knot (10 pulses per 1.69ft of wind, resolution = 5.15cm)
  • A100M Output Cal.:
  • 10Hz per m/s (10 pulses per metre of wind, resolution = 10cm)
  • A100S Output Cal.:
  • 0.8Hz per m/s (1 pulses per 1.25 metre of wind, resolution = 125cm)
  • Rotor:
  • 3-cup R30K (A100K), R30M (A100M) or R30S (A100S) as standard.
  • Dimensions:
  • This instrument is constructed using our standard rotor and anemometer body design and dimensions.
  • Wiring/Connections (Cable colours):
  • For wiring details click HERE
  • Cable:
  • 3m (9ft10in) permanently attached 4-conductor* cable with braided shield/screen as standard. Longer lengths are available to order (up to 115m). Spec: Def Stan 61-12 part 4, 0.22mm²(∼24AWG). *Note: 8-conductor used for /HE4 models.
  • Regulatory/Certifications: :
  • UKCA CE marks CE and UKCA Marked for RoHS3 (RoHS2+Phthlatales amendments) and EMC

    Notes:
    Recommendations:
  • Obtaining best accuracy
  • Reliability & Safety
  • Specifications are correct at time of writing and may change without notice. Please contact us to confirm the latest specifications.

    Common Questions:


    Additional Information:

    This instrument is commonly used in conjunction with our W200P Windvane.
    FAQ: IP Ratings
     
    Please call/email us if you would like access to additional product information, data and specification sheets for this product.
    Windspeed Ltd (Vector Instruments)
    Windspeed Limited (trading as Vector Instruments),
    113 Marsh Road, RHYL, North Wales, LL18 2AB, United Kingdom
    Tel: +44 (0) 1745 350700
    Email: sales@windspeed.co.uk
     
    Website design and content is copyright (c) 2003-2024 Windspeed Limited (unless otherise stated). All trademarks are acknowledged.