Anemometers and Windvanes in action!
Windspeed Ltd (Vector Instruments), 113 Marsh Road, RHYL, N. Wales, LL18 2AB, United Kingdom.
Windspeed Limited
Click for info on: Wind Speed sensors Click for info on: Wind Direction Sensors Click for info on: Masts + Mountings Click for info on: Air Temperature sensors Click for info on: Masts + Mountings Anemometer, Windvane and Air Temperature sensors
 Thursday, December 26 2024  Home [arrow]  Products [arrow]  Signal Conditioners [arrow]  CHM Systems Search site:  

Latest Weather...
(Rhyl, N.Wales, UK)
Wind Speed:  3.6 mph
Wind Direction:  189 °
Air Temp.:  4.6 °C
Rel. Humidity:  100 %
Rain (last Hr):  0.0 mm
(updated at: 07:43 UTC)



Please call/email us if you need:





Translate using Google:
====
====
====
======


Notes:
This website requires Javascript and Cookies to be enabled for correct operation. Privacy Policy...

Use subject to Terms & Conditions.


GDPR: to request or decline communications containing marketing, news & updates from us, click HERE.
Celebrating more than 50 years manufacturing & servicing High Quality Vector Instruments Anemometers and Windvanes at Windspeed Ltd
CHM Series Windspeed and Direction Signal Conditioners
 
NOTE: THIS PRODUCT IS NO LONGER AVAILABLE.
Please contact us if you require service or spares for existing units.

The CHM Series windspeed/direction signal conditioner/alarm set is based around a 24V DC powered Chameleon 'intelligent' DIN rail mounted signal conditioning module and provides conditioned 4-20mA, 0-20mA, or 0-10v (etc) analog outputs with the option of upto two volt-free alarm contacts.

A matching PSU-S82K DIN rail power unit can be provided pre-wired to the chameleon module when a system needs to be mains powered.

The CHM and PSU modules are NOT weatherproof and must be mounted indoors in a suitable enclosure or in an existing control/wiring cabinet. Modules are normally supplied mounted to a short section of DIN rail for this purpose.
This system uses our A100L2 anemometer and W200P windvane. Both the anemometer and windvane signals are linearised appropriately (to correct for rotor and loading non-linearity respectively) and wind speed and direction averages are calculated using a recursive filter/average giving an 'RC' style average equivalent to that used in all our previous systems.

The configuration of the software programmable chameleon module can be altered to accommodate most customer needs, eg different averaging times, windspeed ranges, output signal types/ranges, or to allow the use of upto two volt-free contacts for wind speed and/or wind direction alarms. Correct operation of the modules can be monitored using a relay contact which opens in the event of a fault causing system reset, or a power failure (only one alarm contact possible if this feature required). The alarm contacts should be used to drive a slave relay or contactor when switching mains rated or heavy current loads.

Input/output connections to the chameleon are via un-pluggable screw terminal blocks. The system provides '3-port' galvanic isolation, i.e. the sensors are isolated from the power supply input which is itself isolated from the analog output signals. Note that the analog outputs are not isolated from each other, however a standard DIN rail mounted isolator can be used to overcome this.

Datasheet: login to download
NOTE: THIS PRODUCT IS NO LONGER AVAILABLE.
Specification Highlights:

  • Wind Speed Range:
  • 0..25 m/s as standard (other ranges to order)
  • Wind Direction Range:
  • 0..360°
  • Wind Speed Sensor:
  • A100L2 anemometer
  • Wind Direction Sensor:
  • W200P windvane
  • Output Signals:
  • 4-20mA, 0-20mA, 0-10V (or 0-5V**, 0-10mA**)
  • Output Resolution:
  • 0.09% FSD (10bits)
  • Averaging:
  • 30 sec ('rc' style), others to order.
  • Supply Voltage:
  • 24V DC +/-10%
  • Supply Current:
  • 350mA maximum (typically 150-200mA)
  • Temperature Range:
  • 0..+50°C operating (-40..+70°C storage)
  • Operating Humidity:
  • 0..90%RH (non-condensing). This unit is NOT weatherproof and MUST be installed indoors in a suitable enclosure/wiring cupboard.
  • Output Load:
  • Current Output: 500 Ohms maximum
    Voltage Output: 1K Ohms minimum
  • Output Relays:
  • Two rated at 3A@240VAC***. One is normally configured as a 'fault' alarm (opens on fault), and the other (or both) can optionally be configured as a fixed windspeed/direction alarm.
  • Isolation:
  • Full 3-port galvanic isolation to 500V DC (input/output/power supply). Note that outputs are NOT isolated from each other, however, a separate isolator can be used if necessary.

    Notes:
    ** Uses only part of output range, so resolution is reduced accordingly. For some applications, it may be better to use the standard/full output and use a different current shunt (or voltage divider) at the measuring end.
    *** We advise the use of an additional slave relay/contactor when switching heavy loads or when switching anything other than small loads such as a warning lamp/siren.
    Specifications are correct at time of writing and may change without notice. Please contact us to confirm the latest specifications.
     
    Windspeed Ltd (Vector Instruments)
    Windspeed Limited (trading as Vector Instruments),
    113 Marsh Road, RHYL, North Wales, LL18 2AB, United Kingdom
    Tel: +44 (0) 1745 350700
    Email: sales@windspeed.co.uk
     
    Website design and content is copyright (c) 2003-2024 Windspeed Limited (unless otherise stated). All trademarks are acknowledged.